Firmware – HP Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem User Manual

Page 29

Advertising
background image

Command line 29

Item Description

BootPort (optional)

The target WWPN of the controller interface on the Fibre Channel storage
target. The port name is a 64-bit identifier in the format:

NN:NN:NN:NN:NN:NN:NN:NN, where N is a hexadecimal number

BootLun (optional)

The LUN of the volume used for SAN boot. Valid values include an integer

from 0-255 or 16 hex digits (HP-UX only).

Examples

->set fc-connection MyProfile 1 Fabric=SAN_5
Changes the fabric of an FC SAN fabric connection

->set fc-connection RedProfile 2 Fabric=""
Sets a FC SAN fabric connection to "Unassigned"

->set fc-connection BlueProfile 1 Fabric=SAN_7
Changes the FC SAN fabric of an FC SAN connection

->set fc-connection BlueProfile 1 Speed=4Gb
Changes the port speed of an FC SAN connection

->set fc-connection BlueProfile 1 BootPriority=Primary

BootPort=50:06:0B:00:00:C2:62:00 BootLun=5
Changes the SAN boot priority and sets additional boot parameters

Item Description

show fc-connection

Display the FC SAN connections associated with the server profiles.

Syntax

show fc-connection <ConnectionID>

Parameter

ConnectionID

(optional)

The ID of an existing FC SAN connection. The ID format is
<ProfileName:Port>. <ProfileName:*> can be used to display all the FC SAN

connections of a profile. '*' displays all the FC SAN connections existing in

the domain.

Examples

->show fc-connection
Displays all FC SAN connections existing in the domain

->show fc-connection Profile1:*
Displays FC SAN connections of a profile Profile1

->show fc-connection Profile1:1
Displays a specific FC SAN connection of profile Profile1

firmware

Display or update Virtual Connection firmware version.
Support actions: help, show, update

Item Description

show firmware

Display the current version of firmware for all interconnect modules in the domain.

Syntax

show firmware

Examples