Hard drive problems, System completes post but hard drive fails, Hard drive is not recognized by the server – HP ProLiant SL165z G7 Server User Manual

Page 40: Server response time is slower than usual

Advertising
background image

Troubleshooting 40

c.

Replace the access panels, and then attempt to restart the server.

2.

Be sure the fan configuration meets the functional requirements of the server. Refer to the server
documentation.

3.

Be sure no ventilation problems exist. If you have been operating the server for an extended period
of time with the access panel removed, airflow may have been impeded, causing thermal damage
to components. Refer to the server documentation for further requirements.

4.

Be sure no POST error messages are displayed while booting the server that indicate temperature
violation or fan failure information. Refer to the server documentation for the temperature
requirements for the server.

5.

Replace any required non-functioning fans and restart the server. Refer to the server documentation
for specifications on fan requirements.

6.

Be sure all fan slots have fans or blanks installed. Refer to the server documentation for requirements.

7.

Verify the fan airflow path is not blocked by cables or other material.

Hard drive problems

System completes POST but hard drive fails

Action:

1.

Be sure no loose connections (on page

22

) exist.

2.

Be sure no device conflict exists.

3.

Be sure the hard drive is properly cabled and terminated if necessary.

4.

Be sure the SCSI cable is working by replacing it with a known functional cable.

5.

Run Insight Diagnostics ("

HP Insight Diagnostics

" on page

20

) and replace failed components as

indicated.

Hard drive is not recognized by the server

Action:

1.

Check the LEDs on the hard drive to be sure they indicate normal function. Refer to the server
documentation or the HP website for information on hard drive LEDs.

2.

Be sure no loose connections (on page

22

) exist.

3.

Remove the hard drive and be sure the configuration jumpers are set properly.

4.

If using an array controller, be sure the hard drive is configured in an array. Run the array
configuration utility.

5.

Be sure the drive is properly configured. Refer to the drive documentation to determine the proper
configuration.

6.

If it is a non-hot-plug drive, be sure a conflict does not exist with another hard drive. Check for SCSI
ID conflicts.

7.

Be sure the correct drive controller drivers are installed.

Server response time is slower than usual

Action: Be sure the hard drive is not full, and increase the amount of free space on the hard drive, if
needed. It is recommended that hard drives should have a minimum of 15 percent free space.

Advertising