Expanding thp/smart volumes – HP XP P9000 Command View Advanced Edition Software Licenses User Manual

Page 76

Advertising
background image

Prerequisites

Before you delete THP/Smart pools, first unallocate the THP/Smart volumes that belong to the THP/
Smart pools to be deleted.

NOTE:

When you delete a THP/Smart pool, Command View AE Suite automatically performs an immediate
quick format only on those volumes that were THP/Smart pool volumes, but became basic volumes
because the associated THP/Smart pools were deleted. This allows these basic volumes to be used
again. A best practice for deleting a pool is to run this task when system activity is low and major
system operations are not running.

1.

On the Resources tab, select Storage Systems.

2.

Expand the tree, select the target storage system, and select THP Pools.

3.

From the list of pools, select one or more target THP/Smart pools to delete, and click Delete Pools.

4.

In the Delete Pool dialog box, confirm that the information matches the THP/Smart pools to be
deleted.

Optionally, update the task name and provide a description.

5.

Click Submit.

The delete THP/Smart pools process begins.

6.

You can check the progress and the result of the delete THP/Smart pools task on the Tasks &
Alerts tab

Verify the results for each task by viewing the details of the task.

The deleted THP/Smart pool no longer appears in the THP/Smart pool list for the target storage
system.

Related topics

About virtualizing storage capacity

, page 65

Creating a THP/Smart pool

, page 66

Expanding THP/Smart volumes

You can expand the size of a THP/Smart volume to expand its capacity.

1.

On the Resources tab, select Storage Systems in the navigation tree.

2.

Expand the tree for the target storage system that includes the pool you want to modify, and
select the THP/Smart pool in THP Pools.

3.

On the THP Vols tab, select one or more volumes you want to expand and click Expand THP
Volume.

4.

Specify the new capacity for the volume.

5.

Click Submit.

6.

On the Tasks & Alerts tab, confirm that all tasks are completed.

7.

In the Storage Systems tree, return to the target storage system, click the target THP/Smart pool
and view the THP Vols tab to confirm that the information is updated.

Managing storage resources in a SAN environment