HP StorageWorks XP48 Disk Array User Manual

Page 198

Advertising
background image

Troubleshooting 198

Table 11-18

Messages Common to Provisioning Manager Components

Error Code

Error Message

Description and Recommended Action

KARF99000-W

The value specified for
logger.MaxBackupIndex in logger.properties
is invalid, so the default value will be set and
used for startup.

Cause: An invalid value is set for the setting
logger.MaxBackupIndex in the property file
logger.properties.
Action: Check the value of logger.properties.

KARF99001-W

The value specified for logger.MaxFileSize in
logger.properties is invalid, so the default
value will be set and used for startup.

Cause: An invalid value is set for the setting
logger.MaxFileSize in the property file
logger.properties.
Action: Check the value of logger.properties.

KARF99002-W

The value specified for logger.sysloglevel in
logger.properties is invalid, so the default
value will be set and used for startup.

Cause: An invalid value is set for the setting
logger.sysloglevel in the property file
logger.properties.
Action: Check the value of logger.properties.

KARF99003-W

The value specified for logger.loglevel in
logger.properties is invalid, so the default
value will be set and used for startup.

Cause: An invalid value is set for the setting
logger.loglevel in the property file
logger.properties.
Action: Check the value of logger.properties.

KARF99004-I

A value for logger.MaxBackupIndex in
logger.properties is not specified, so the
default value will be set and used for startup.

Cause: A value for logger.MaxBackupIndex in
logger.properties is not specified.
Action: If necessary, specify the value in
logger.properties.

KARF99005-I

A value for logger.MaxFileSize in
logger.properties is not specified, so the
default value will be set and used for startup.

Cause: A value for logger.MaxFileSize in
logger.properties is not specified.
Action: If necessary, specify the value in
logger.properties.

KARF99006-I

A value for logger.sysloglevel in
logger.properties is not specified, so the
default value will be set and used for startup.

Cause: A value for logger.MaxFileSize in
logger.properties is not specified.
Action: If necessary, specify the value in
logger.properties.

KARF99007-I

A value for logger.loglevel in logger.properties
is not specified, so the default value will be
set and used for startup.

Cause: A value for logger.loglevel in
logger.properties is not specified.
Action: If necessary, specify the value in
logger.properties.

KARF99008-W

An attempt to load the logger.properties file
has failed. The default values for all settings
will be set and used for startup.

Cause: The property file (logger.properties) could
not be read.
Action: Check the logger.properties file.

Advertising
This manual is related to the following products: