Retaining the recovery key/password, Enabling the trusted platform module – HP ProLiant ML370 G6 Server User Manual

Page 101

Advertising
background image

Hardware options installation 101

11.

Install the TPM security rivet by pressing the rivet firmly into the system board.

12.

Install the fan cage.

13.

Install the air baffle.

14.

If removed, install the BBWC battery pack or the FBWC capacitor pack ("

Installing the BBWC battery

pack or the FBWC capacitor pack

" on page

86

).

15.

Install fan 5.

16.

Install the access panel.

17.

Do one of the following:

o

Close or install the tower bezel, as needed.

o

Install the server in the rack.

18.

Power up the server (on page

22

, "

Powering up and configuring the server

" on page

40

).

Retaining the recovery key/password

The recovery key/password is generated during BitLocker™ setup, and can be saved and printed after
BitLocker™ is enabled. When using BitLocker™, always retain the recovery key/password. The recovery

key/password is required to enter Recovery Mode after BitLocker™ detects a possible compromise of system

integrity.
To help ensure maximum security, observe the following guidelines when retaining the recovery
key/password:

Always store the recovery key/password in multiple locations.

Always store copies of the recovery key/password away from the server.

Do not save the recovery key/password on the encrypted hard drive.

Enabling the Trusted Platform Module

1.

When prompted during the start-up sequence, access RBSU by pressing the F9 key.

2.

From the Main Menu, select Server Security.

Advertising
This manual is related to the following products: