Option rom configuration for arrays – HP ProLiant ML370 G6 Server User Manual

Page 120

Advertising
background image

Software and configuration utilities 120

Provides different operating modes, enabling faster configuration or greater control over the

configuration options

Remains available any time that the server is on

Displays on-screen tips for individual steps of a configuration procedure

Beginning with ACU version 8.28.13.0, provides diagnostic functionality on the Diagnostics tab
(formerly known as Array Diagnostics Utility).

For optimum performance, the minimum display settings are 1024 × 768 resolution and 16-bit color. Servers

running Microsoft® operating systems require one of the following supported browsers:

Internet Explorer 6.0 or later

Mozilla Firefox 2.0 or later

For Linux servers, see the README.TXT file for additional browser and support information.
For more information, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the

Documentation CD or the HP website (

http://www.hp.com

).

Option ROM Configuration for Arrays

Before installing an operating system, you can use the ORCA utility to create the first logical drive, assign

RAID levels, and establish online spare configurations.
The utility also provides support for the following functions:

Reconfiguring one or more logical drives

Viewing the current logical drive configuration

Deleting a logical drive configuration

Setting the controller to be the boot controller

If you do not use the utility, ORCA will default to the standard configuration.
For more information regarding array controller configuration, refer to the controller user guide.
For more information regarding the default configurations that ORCA uses, refer to the HP ROM-Based Setup
Utility User Guide
on the Documentation CD.

Re-entering the server serial number and product ID

After you replace the system board, you must re-enter the server serial number and the product ID.

1.

During the server startup sequence, press the F9 key to access RBSU.

2.

Select the Advanced Options menu.

3.

Select Service Options.

4.

Select Serial Number. The following warnings appear:
WARNING! WARNING! WARNING! The serial number is loaded into the system during

the manufacturing process and should NOT be modified. This option should only

be used by qualified service personnel. This value should always match the

serial number sticker located on the chassis.
Warning: The serial number should ONLY be modified by qualified personnel.

This value should always match the serial number located on the chassis.

5.

Press the Enter key to clear the warning.

Advertising