Specifications, Environmental specifications, Server specifications – HP ProLiant ML370 G6 Server User Manual

Page 155: Power supply specifications

Advertising
background image

Specifications 155

Specifications

Environmental specifications

Specification

Value

Temperature range*

Operating

10°C to 35°C (50°F to 95°F)

Shipping

-40°C to 70°C (-40°F to 158°F)

Maximum wet bulb temperature 28°C (82.4°F)
Relative humidity
(noncondensing)**

Operating

10% to 90%

Non-operating

5% to 95%

* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3048

m (10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for

storage corresponds to a pressure minimum of 70 kPa.

Server specifications

Specification

Value

Dimensions

Rack model

Height

17.48 cm (6.88 in)

Depth

69.93 cm (27.53 in)

Width

48.34 cm (19.03 in)

Tower model

Height

47.04 cm (18.52 in)

Depth

73.96 cm (29.12 in)

Width

24.77 cm (9.75 in)

Weight

Weight (when lightly loaded) —
Rack

25.00 kg (55.12 lbs)

Tower

30.00 kg (66.14 lbs)

Weight (maximum)

46.75 kg (103.06 lbs)

Power supply specifications

Depending on installed options, the server is configured with one of the following power supplies:

Advertising
This manual is related to the following products: