Operations 27

IMPORTANT:

When installing or replacing server components, one or more fans might need to

be removed. To prevent an orderly or immediate server shutdown, HP highly recommends

powering down the server during these procedures. To determine if powering down is required,
see the specific procedure.

To remove the component:

1.

Power down the server (on page

22

).

2.

Do one of the following:

o

Open or remove the tower bezel, as needed ("

Open or remove the tower bezel

" on page

22

).

o

Extend the server from the rack (on page

24

).

3.

Remove the access panel (on page

25

).

4.

Remove the fan from the air baffle.

To replace the component, reverse the removal procedure.

Remove the BBWC battery pack or the FBWC

capacitor pack

CAUTION:

To prevent a server malfunction or damage to the equipment, do not add or remove

the battery pack while an array capacity expansion, RAID level migration, or stripe size migration

is in progress.

CAUTION:

After the server is powered down, wait 15 seconds and then check the amber LED

before unplugging the cable from the cache module. If the amber LED blinks after 15 seconds, do
not remove the cable from the cache module. The cache module is backing up data, and data is

lost if the cable is detached.

To remove the component:

1.

Power down the server (on page

22

).

2.

Do one of the following:

Advertising