Memory options – HP ProLiant ML370 G6 Server User Manual

Page 46

Advertising
background image

Hardware options installation 46

14.

Install the heatsink, and then close the heatsink retaining latches.

15.

Install the air baffle.

16.

If removed, install the BBWC battery pack or the FBWC capacitor pack ("

Installing the BBWC battery

pack or the FBWC capacitor pack

" on page

86

).

17.

Install fan 5.

18.

Install the access panel.

19.

Do one of the following:

o

Close or install the tower bezel, as needed.

o

Slide the server back into the rack.

20.

Power up the server (on page

22

, "

Powering up and configuring the server

" on page

40

).

Memory options

IMPORTANT:

This server does not support mixing RDIMMs and UDIMMs. Attempting to mix

these two types causes the server to halt during BIOS initialization.

The memory subsystem in this server can support RDIMMs or UDIMMs. Both types are referred to as DIMMs

when the information applies to both types. When specified as RDIMM or UDIMM, the information applies
to that type only. All memory installed in the server must be the same type.
The server supports the following DIMM speeds:

Single- and dual-rank PC3-10600 (DDR-1333) DIMMs operating at 1333 and 1066 MHz

Quad-rank PC3-8500 (DDR-1067) DIMMs operating at 1066 MHz

Depending on the processor model, the number of DIMMs installed, and whether UDIMMs or RDIMMs are
installed, the memory clock speed may be reduced to 1066 or 800 MHz. For more information on the effect

of DIMM slot population, see "General DIMM slot population guidelines (on page

50

)."

Advertising
This manual is related to the following products: