NOTE:

If you configure alarms at the host group level, and then edit a host in any port, the alarm
notification is sent only for the common host group that is configured. The notifications are
not sent for the edited host group. To receive notifications for the edited host group, re-configure
the alarms.

If you change the name of a host group that has alarms configured, delete and re-configure
all alarms for that host group.

Selecting components and metrics

You can configure alarms on XP and P9000 disk arrays, corresponding component types, or
individual components. To select components and metrics:
1.

Click PA and DB Settings+Alarms in the left pane.

2.

In the component selection tree under Data Source, select components on which you want to
configure alarms. For more information on selecting components and related metrics, see

“Selecting components and metrics” (page 238)

.

You can also search for components on which you want to configure alarms. For more
information, see

“Searching for components” (page 128)

.

3.

Click Add alarm(s). The Add alarm(s) button is enabled only when you select a component in
the component selection tree and related metrics in the Available Metrics Choose Metric
Category list.

The records are automatically displayed in the Alarms table. Select the particular XP or P9000
disk array, or component in the component selection tree to view the corresponding set of
records in the Alarms table. Initially, when alarms are not yet configured on the selected
components, the following informational message No alarms are configured for the given
filters. appears above the Alarms table.

The following are examples on selecting components and adding records for them in the Alarms
table:

Adding record for a P9000 disk array:

The P9000 disk array selected is 53046 in the component selection tree (see following image).

The corresponding metric selected in the Available Metrics Choose Metric Category box is SM
CHIP BUS/Path Util.

When you click Add alarm(s), the record pertaining to 53046 and the SM CHIP BUS/Path Util
metric is added to the Alarms table. The Resource column displays All, which implies that the alarm
is configured within the scope of the selected metric on all the components in 53046.