Table 13 VCEM operations and RBAC privileges (continued)

VCEM user
(Read-only)

VCEM group
limited operator

VCEM group
operator

VCEM group
administrator

VCEM
administrator

VCEM operations
or VCEM roles

N

N

N

x

x

Delete VC
Domain Group

N

N

N

x

x

Upgrade VC
Domain Group
firmware mode

N

N

N

x

x

Update VC
Domain firmware

N

N

N

N

x

License Enclosure

Adding a VC Domain to a VC Domain Group

Select Add to VCD Group to add a VC Domain to a VC Domain Group. Verify that the following
prerequisites are met:

At least one VC Domain Group is created

Your current selection contains VC Domains that do not belong to a VC Domain Group

VC Domains have a valid license

Ensure that the version of VC firmware and the features enabled in the VC Domain are
compatible with the group firmware mode of the VC Domain Group to which it is being added.
For more information, see

“Mixed VC firmware versions and compatibility in a VC Domain

Group ” (page 20)

.

The VC Domains you select have a supported VC firmware version

If the VC firmware is unsupported, the following error message is displayed:

The operation cannot be performed because the VC firmware version

for the selected VC Domain(s) is not supported by VCEM. Refer to

the VCEM User Guide to verify the supported VC firmware versions,

and then update the VC Domain(s) firmware to a supported version.

The VC Domain as well as the VC Domain Group configuration for the configured VC Domains
meet the minimum requirements . For the complete list of configuration checks, see

“Requirements for adding a VC Domain to a VC Domain Group” (page 30)

.

To manage multi-enclosure VC Domains in VCEM, you must perform the following steps before
adding a VC Domain to a VC Domain Group:
1.

Log in to VCM.

2.

Find and import a local enclosure, and then select the appropriate Double-dense option.

3.

Skip the Network and Fibre Channel configuration wizards, and then navigate directly to the
VC Domain user interface.

4.

From VCM, find and import the necessary remote enclosures in the correct order. For more
information on remote enclosures, see the HP Virtual Connect for c-Class BladeSystem Setup
and Installation Guide
at

http://bizsupport1.austin.hp.com/bc/docs/support/SupportManual/

c01732252/c01732252.pdf

.

5.

From Systems Insight Manager, perform a manual discovery of the Onboard Administrator IP
address for all remote VC Domain enclosures.