Detailed zoning examples, Set up a fabric zone configuration, Chapter 5 – HP Surestore 6164 Switch User Manual

Page 25: Chapter 5 detailed zoning examples

Advertising
background image

Zoning User’s Guide

5-1

Chapter

5

Detailed Zoning Examples

The following examples illustrate setting up a zone configuration. Note that changes have been
saved periodically to facilitate switching from one configuration to another. In addition to the
periodic saves, the cfgShow command has been issued to display current status to verify that
changes have been processed.

Set Up a Fabric Zone Configuration

A configuration named “cfg1” is established by using the cfgCreate command.

test181:admin> “cfg1”, “ql_zone1; ql_zone2; fabric_zone1; fabric_zone2”

Set Up QuickLoop and Fabric Zones on Dual
Switch Configuration (Mixed Mode Environment)

The following example illustrates setting up QuickLoop and Fabric Zones in a mixed mode environment. This
configuration consists of ports that are set to QuickLoop and Fabric modes.

test181:admin> cfgShow

Defined configuration

no configuration in effect

Effective configuration:

no configuration in effect

On switch 1...

<Set QuickLoop partner and enable QuickLoop ports on switch 1>

test180_Jr:admin> qlPartner “10:00:00:60:69:00:00:22”

Setting Quick Loop to dual-switch mode,

Committing configuration...done.

test180_Jr:admin>

test180_Jr:admin> qlPortEnable1

Setting port to Quick Loop mode,

Committing configuration...done.