Specification Revised 3/14

370231

GTDX180ED/185ED

GE

®

6.0 cu. ft. capacity DuraDrum

electric dryer

Electric Dryer Rating:

240V

5600W

24A

60Hz

208V

4400W

22A

60Hz

Exhaust Option: 4-way rear, right, left
and bottom
Circuit Requirements: An individual,
properly-grounded branch circuit, protected
by a 30-amp circuit breaker or a time-delay
fuse, is required.
Note: Dryer wall outlet must be located within
36" of service cord entry and acessible when
dryer is mounted in position.
Installation Information: For complete
information, see installation instructions
packed with your dryer.

Dimensions and Installation Information (in inches)

Special Installation Requirements
Alcove or Closet Installation:

• If your dryer is approved for installation in an alcove or closet, it will be stated on a label

on the dryer back.

• The dryer MUST be exhausted to the outside.

• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:

0" either side; 3" front and rear

• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”.

• Closet doors must be louvered or otherwise ventilated and must contain a minimum

of 60 sq. in. of open area equally distributed. If this closet contains both a washer and

a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.

• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:

• The dryer MUST be exhausted to the outdoors.

• The installation must conform with the local codes, or in the absence of local codes,

with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.

Minimum Clearances other than Alcove or Closet Installation:

• Minimum clearances to combustible surfaces are: 0" both sides; 3" rear
Dryer Exhausting Information : Use metal duct only, vertical and horizontal ducting.