USE TOP CABINET TEMPLATE
FOR PREPARATION OF TOP
CABINET

B3.

Read the instructions on the TOP CABINET

TEMPLATE.

Tape it underneath the top cabinet.
Drill the holes, following the instructions on the

TOP CABINET TEMPLATE.

CAUTION:

Wear safety goggles when

drilling holes in the cabinet bottom.

Wall

Mounting

Plate

Spacing for Toggles More
Than Wall Thickness

Toggle
Bolt

Toggle Wings

To use toggle bolts:

Bolt End

Installation Instructions

You need to drill holes for the top support screws and
a hole large enough for the power cord to fit through.

Place the mounting plate against the wall and
insert the toggle wings into the holes in the wall
to mount the plate.

NOTE: Before tightening toggle bolts and wood
screw, make sure the tabs on the mounting plate
touch the bottom of the cabinet when pushed flush
against the wall and that the plate is properly
centered under the cabinet.

CAUTION:

Be careful to avoid

pinching fingers between the back of the mounting
plate and the wall.

Tighten all bolts. Pull the plate away from the wall
to help tighten the bolts.

3

4

BEFORE: Fan Blade
Openings Facing Up

3

1

ADAPTING MICROWAVE
BLOWER FOR OUTSIDE
BACK EXHAUST

B4.

End B

End A

Carefully pull out the blower unit. The wires
will extend far enough to allow you to adjust the
blower unit.

2 Open the blower door by lifting it up at the back

of the microwave oven. Remove and save the
blower retaining screw.

Blower Retaining
Screw

Remove and save the screw that holds the blower
motor door closed on the back and the blower
retaining screw on the top of the door.

Back of
Microwave
Oven

Blower Motor
Door Retaining
Screw

Blower

Blower
Retaining
Screw