Upgrading port controllers – AMX UDM-0102 User Manual

Page 71

Advertising
background image

Advanced Administration

59

UDM-0102 and UDM-RX02 Operation/Reference Guide

6.

A successful transfer message should be returned. This may appear after a minute or so depending
on network environment and size of file.

7.

The command window can be closed.

8.

The network connection to the hub will be broken as the hub will reset. It is recommended that the
hub is powered off then powered on at this point.

Upgrading Port Controllers

Ensure the TFTP client has been installed on the PC which will be used to send files to the hub. Install
tftp client: if necessary, consult with Endeleo support as to the appropriate client.

1.

Run the client.

2.

Start a command session on the PC. Change to the directory where the .ROM files are stored on the
PC e.g. cd\hub.

3.

Type in the following command at the prompt observing the parameters below;

tftp –i [IP address] PUT [filename].[portnumber]

4.

For example, typing in tftp –i 192.168.0.96 PUT R26201610800.001 will upload the
file R26201610800 to the UDM hub with IP address 192.168.0.96 (FIG. 83).

FIG. 82

Issuing tftp commands to the Hub

If you experience problems with TFTP, try opening a hyperterminal session to the
UDM at the same time, so that you can see the bytes loading.