Instruction Sheet

Indy 440-1

INS-07238

THESE INSTRUCTION SHEETS ARE INTENDED AS REPRESENTATIONS ONLY. JESEL IS IN NO EVENT LIABLE FOR CONSEQUENTIAL DAMAGE,

INSTALLATION COST OR OTHER COST OF ANY NATURE. NO REPRESENTATIVE IS AUTHORIZED TO ASSUME FOR JESEL ANY OTHER LIABILITY

IN CONNECTION WITH ANY JESEL PRODUCT. NOT RESPONSIBLE FOR TYPOGRAPHICAL ERRORS.

www.jesel.com

2.150”

0.875”

1.144”

2.250”

0.972”

1.166”

2.350”

1.070”

1.189”

DIM B

DIM C

DIM A

Machining Instructions:

NOTE:

Datum Point is the head bolt hole directly behind cylinder

#3 & 5 exhaust valves. Machine mounting surface for rocker

stand parallel with deck surface.

1)

MEASURE VALVE TIP TO SPRING SEAT DIMENSION

(DIM A) AND REFER TO CHART BELOW FOR X & Y

COORDINATES.

2)

MILL

EXISTING

ROCKER

PEDISTALS

TO

THE

APPROPRIATE HEIGHT (DIM B). THE ZERO POINT FOR

DIMENSION B IS THE BOTTOM OF THE HEAD BOLT

COUNTERBORE.

3)

SET THE X & Y ZERO TO THE CENTER OF THE

HEAD BOLT REFERENCED ABOVE. DETERMINE THE Y+

DIMENSION FROM CHART BELOW (DIM C).

4)

DRILL AND TAP FOR 7/16-14 x 1.000” STAND MOUNTING

BOLTS

TO

DIMENSIONS

SHOWN

ABOVE.

IT

IS

NORMAL TO BREAK INTO THE INTAKE RUNNERS. USE

APPROPRIATE

THREAD

SEALANT

ON

BOLTS

BEFORE

FINAL INSTALLATION OF ROCKER STAND.

Z COORDINATE

VALVE HEIGHT

Y COORDINATE

X+

Y+

Z+