Minimum cabinet requirements, Minimum requirements below cooktop, Duct locations – Amana AKES3060 User Manual

Page 6

Advertising
background image

6

L

Duct Locations

Cooktop can be vented vertically or horizontally. If vented
horizontally, vent air through exterior to left or rear wall if
possible. If vented vertically, locate hole between floor
joists.

If cooktop is installed in island above wall oven, vent
horizontally and then vertically. Confirm adequate spacing
on left side or rear of island for duct.

A

B

C

D

E

F

L

C

L

G

A—6 inches
B—4

7

/

32

inches

C—Center line of cutout
D—12½ inches
E—Back edge of cutout
F—10½ inches
G—4

3

/

8

inches between top of counter and top of

duct cutout.

Minimum Cabinet Requirements

Single cabinet installation requires a 36-inch width base
cabinet.

Minimum Requirements Below Cooktop

• Shaded blower area is 7

7

/

8

inches deep from top of

countertop to blower bottom.

• Unshaded cutout area is 4 inches deep from top of

countertop to burner box bottom.

Top View

A

B

C

Front

A—Edge of cutout
B—8

3

/

16

inches

C—6

7

/

16

inches

Front View

D

E

D—4 inches
E—7

7

/

8

inches

Side View

F

G

Front

F—4 inches
G—7

7

/

8

inches