Duct Connections

•` Blower exhaust faces towards rear wall. Connect

blower exhaust to ducting with 3¼ x 10 piece. No
screws are necessary.

• Do not install 2 elbow fittings next to each other. Two

elbow fittings joined together create unusual air
patterns and can result in poor ventilation.

• Do not vent into an attic or crawl space. Always vent

outside.

• Seal all joints in venting system with duct tape to avoid

smoke or odor in home.

• Do not use laundry wall caps. Wall cap must have

minimum of 28 square inches free air space.

Blower Exhaust

Ducting

Adjustable transition piece

Duct Length

Maximum allowable calculated duct length is 60
equivalent feet.
• Use “Duct Length Piece Equivalents” section to

calculate duct length.

Flexible duct is not recommended. However, if it is

used, one foot of flexible duct is equal to two feet of
smooth metal duct.

Duct Length Piece Equivalents

x 10 inch ducting pieces

x 10 inch to 6 inch

transition = 5 equivalent
foot

x 10 inch to 6 inch

transition = 4½
equivalent feet

x 10 inch flat elbow =

12 equivalent feet

x 10 inch 90 degree

elbow = 5 equivalent feet

x 10 inch wall cap

(Unrestricted) = 0
equivalent feet