A.R.I. S014-S016 EN User Manual

A.r.i, Automatic air release valves

Advertising
background image

Installation and Maintenance of
A.R.I.’s S-014,S-016

Automatic Air Release Valves


C. Basic,

Periodic,

Maintenance

B.1

Shut the isolating valve below the air valve.

B.2

Unscrew the cover’s bolts of the automatic air valve (9) slowly,to release
accumulated pressure .

B.3

Remove the cover of the automatic a.r.v. (4) , clean the orifice (5) with flowing
water and with thin copper wire

.

Wash the inside of the body(12), the float(11), and the Rolling Seal (6), with
clean water

.

B.4

Check to make sure the Rolling Seal is unharmed (not torn or cracked) .

B.5

Reinstall in reverse order and fasten and tighten all bolts. Make sure to re-
assemble all the components correctly.

B.6

Open the isolating valve beneath the air valve.

A. Installation

A.1

The air valve will be mounted on a riser,
connected to the top of the pipe.

A.2

An isolating valve will be installed below the air
valve.

B. Operation

The

S-014

,

S-016

Automatic Air Release valve, releases entrapped air from peaks of pressurized

systems where the valve should be installed.

Pockets of accumulated air may cause the following destructive phenomena:

*. Impediment of effective flow and hydraulic conductivity of the system, along with a throttling effect

as would a partially closed valve. In extreme cases this will cause complete flow stoppage.

*. Accelerate cavitation damages.

*. High pressure surges.

*. Accelerate corrosion of metal parts.

*. Danger of a high-energy burst of compressed air.

*. Inaccuracies in flow metering.


FLOW CONTROL ACCESSORIES

Tel. 972-4- 6761980 Fax.972-4- 6763402

A.R.I