Haws 3500FR User Manual

Page 2

Advertising
background image

04/10

Model 3500FR

Page 2 of 4

RECOMMENDED TOOLS: Hack saw, pipe joint sealant, screwdriver, level, 12" adjustable
wrench, 10" pipe wrench, 9/16”, 1/2", 7/16” socket wrench or open end wrench, 5/32” hex key
wrench pinned tamper proof (supplied).

LOCATION OF UNIT: The Model 3500FR Drinking Fountain is a wheelchair accessible
drinking water facility. The height dimensions shown, meet current ADA requirements. When
installing this unit, local, state or federal codes should be adhered to. If height other than
shown is required, then dimensions must be adjusted accordingly.

SUPPLY LINE: The minimum recommended line size is 1/2“IPS with 30-90 PSI (2-6 ATM)
flowing pressure. Where sediment or mineral content is a problem, an inlet filter is
recommended.

PLUMBING CONNECTIONS: Waste outlet is female 1-1/2” slip PVC female.

MAINTENANCE:
Refer to 6518.2FR Operation and Maintenance Sheet for more
information.

TROUBLESHOOTING

PROBLEM

REPAIR CHECKLIST

1. Insufficient bubbler flow.

1a. Check that inlet screwdriver stop valve

is wide open.

b. Verify minimum 30PSI flowing supply

pressure.

c. Adjust valve to increase flow. See

6518FR Manual.

General Notes:
Before tightening nut and ferrule assembly, push tubing into fitting until it bottoms out to
ensure correct engagement with O-Ring.







For more information about Haws products, see our website:

www.hawsco.com















© 2010 Haws

®

Corporation – All Rights Reserved

HAWS

®

and other trademarks used

in these materials are the exclusive property of Haws Corporation.