Cleanup, 8 cleanup - flushing the unit, Flushing the unit – Wagner PaintREADY System User Manual

Page 8: Start before you begin, Pull

Advertising
background image

English

8

Cleanup -

Flushing the unit

Start

Before you begin:

When cleaning, use the appropriate cleaning

solution (warm, soapy water for latex materials;

mineral spirits for oil-based materials)

IMPORTanT: never clean nozzle or air holes in

the spray gun with sharp metal objects. Do not

use solvents or lubricants containing silicone.

Special cleanup instructions for use

with flammable solvents (must have

a flashpoint above 70ºF (21ºC):

• Always flush spray gun outside.
• Area must be free of flammable vapors.
• Cleaning area must be well-ventilated.
• Do not submerge turbine!

1. Turn the turbine OFF. Loosen the

material container by 1/2 turn,

but do not remove it. This will

relieve any pressure left over in

the system.

Trigger the spray gun so that the

material inside the spray gun

flows back into the container.

4. Attach the cup to the gun and

plug in the sprayer.

2. Unscrew the container and

remove.

Empty any remaining material

back into the material container.

5. Turn the turbine ON.

Spray the cleaning solution into a

safe area.

While spraying, gently shake the

spray gun. This slight agitation

will help break up smaller

particles of spray material.

3. Pour a small amount of the

appropriate cleaning solution

into the cup.

6. Turn the turbine OFF. Loosen the

material container by 1/2 turn,

but do not remove it. This will

relieve any pressure left over in

the system.

Trigger the spray gun so that the

material inside the spray gun

flows back into the container.

Move on to “Cleanup - Cleaning the

spray gun components”, next page.

4

2

5

3

6

1/2

1/2

1

PULL

Empty waste

container