Horner APG SmartRail HE599DAC106 (current) User Manual

Smartrail, Prefer spring-clamps

Advertising
background image

MAN0932-02-EN

Specifications / Installation

__________________________________________________________________________________________________________________________________________________________________
1/3/2011

Page 1 of 1










1

Specifications

Specifications

DAC101

DAC106

Number of Channels

4

Output Range(s)

0-10V

0-20mA, 4-20mA

Absolute Maximum Output

DC ±15V

DC ±25mA

Resolution

12-Bit (2.5mV)

12-bit (5uA, 4uA)

Maximum Load

>2kΩ

<510Ω

Accuracy

< +/-0.5%

Isolation

500V (backplane)

Conversion Time

1mS/ch

Backplane Power Consumed

110mA @ 5V

External Power Required

62mA @ 24V

120mA @ 24V

Terminal Type

Screw Type, Removable 11-posn

Optional Spring-clamp Plug

HE599TRM011

Storage Temp.

-25° to 70° Celsius

Operating Temp.

-0° to 55° Celsius

Relative Humidity

5 to 95% Non-condensing

Dimensions WxHxD

20mm x 90mm x 60mm

0.79” x 3.54” x 2.36”

Weight

64g (2.3 oz.)

70g (2.5oz.)

CE & UL Compliance

CE, UL & C-UL


2

Wiring – I/O








3

Configuration DATA


The SmartRail Analog Output modules have a variety of parameters configured on a channel-by-
channel basis. These parameters are set using Cscape (9.1 or later), and are listed below:

Cscape Configuration Data – Selectable per channel

Parameter

DAC101

DAC106

Hold Last State
Go to Minimum

Go to Mid-range

Hold Last State

Go to Maximum

4-20mA

Analog Output Range

0-10V

0-20mA




3.1

Output Scaling


The SmartRail Analog Outputs scale digital values from 0-4000, to the analog value (0-10V, 0-
20mA, or 4-20mA). For every digital count the output is incremented, the analog output value will
increment an appropriate amount (2.5mV for 0-10V, 5uA for 0-20mA, 4uA for 4-20mA).



4

Installation / safety






a. All applicable codes and standards should be followed in the installation of this product.
b. Shielded, twisted-pair wiring should be used for best performance.
c. Shields should be grounded at one end only, preferably at the end providing the best noise
shunting.
d. Use the following wire type or equivalent: Belden 8441.

For detailed installation and a handy checklist that covers panel box layout requirements and
minimum clearances, refer to the hardware manual of the controller you are using.

When found on the product, the following symbols specify:






7

Technical Support

Technical Support at the following locations:

North America:
Tel: 317 916-4274
Fax: 317 639-4279
Web:

http://www.heapg.com

Email:

[email protected]

Europe:
Tel: +353-21-4321266
Fax: +353-21-4321826
Web:

http://www.horner-apg.com

Email:

[email protected]








DAC LED Status Indication

LED

Meaning
ON = Normal Operation
FLASH = I/O Error

RUN

OFF = No Power or I/O Error

SmartRail

0-10V or 4-20mA Analog Output Modules

HE599DAC101 (voltage) & HE599DAC106 (current)

12-Bit Resolution

No part of this publication may be reproduced without the prior agreement and written
permission of Horner APG, Inc. Information in this document is subject to change without
notice.

Warning: Remove power from the OCS controller and any peripheral equipment connected
to this local system before adding or replacing this or any module.

Warning: Consult
user documentation.

Warning: Electrical
Shock Hazard.

+

-

24VDC

N.C.

-

CH4

+

-

CH3

+

-

CH2

+

-

CH1

+

24VDC @ 120mA
External Power

SHIELD GROUNDED
AT ONE END ONLY

+

-

+

-

LOAD

+

-

LOAD

+

-

LOAD

+

-

LOAD

DAC106

DAC101

0-20mA
<510 OHM
LOAD

0-10V
>2k OHM
LOAD

Prefer Spring-clamps?

Optional Spring-clamp style plugs are
available as economical wiring accessories.
See specification table for part number(s).
Representative 10-position plug shown.

Advertising
This manual is related to the following products: