TE525 Tipping Bucket Rain Gage

TE525

TE525WS

TE525MM

Height

24.1 cm (9.5 in)

26.7 cm (10.5 in)

29.2 cm (11.5 in)

Tipping Bucket Weight

0.9 kg (2 lb)

1 kg (2.2 lb)

1.1 kg (2.4 lb)

Cable

2-conductor shielded cable

Cable Weight

0.1 kg (0.2 lb) per 10 ft length

7. Operation

7.1 Wiring

When Short Cut is used to generate the datalogger program, the sensor should
be wired to the channels shown on the wiring diagram created by Short Cut.

The rain gage is typically wired to a datalogger’s pulse channel (see TABLE
7-1).

TABLE 7-1. Wiring for Pulse Channel Input






Color


|



Description

CR800
CR850
CR1000
CR3000
CR5000
CR9000(X)




CR510
CR500
CR10(X)




21X
CR7
CR23X





CR200(X)
Series

Black Signal

Pulse
Channel

Pulse
Channel

Pulse
Channel

P_SW

White Signal

Return

G

Clear Shield

G

Dataloggers listed in TABLE 7-2 have the capability of counting switch
closures on some of their control ports. When a control port is used, the return
from the rain gage switch must be connected to +5 V on the datalogger.

TABLE 7-2. Wiring for Control Port Input




Color




Description

CR800
CR850
CR1000
CR3000



CR500
CR510




CR10X




CR23X

Black Signal

Control Port C2/P3

Control Port Control Port

White Signal Return 5 V

5 V

5 V

5 V

Clear Shield

G

9

Advertising