PROGRAMMABLE WALL SWITCH
MODEL TI052A-3W / 3-WAY

FOR ALL LIGHTING

THE MAXIMUM LOAD MUST NOT EXCEED 500W/230V

SINGLE POLE INSTALLATION

When installing, do not connect the red wall switch wire. Make sure the
red wire is correctly capped with a wire nut.

WIRING DIAGRAM

INSTALLATION

This wall switch can be used for either single pole or multiswitch
installation.

A multiswitch installation with an electronic wall switch differs from
conventional installation. Read wiring instructions carefully. Use
guidelines applicable to your installation.

Apply the following steps for all installations.

Note: The black wall switch wires have no polarity. You can use any

of them.

1. Interrupt power at circuit breaker to avoid electric shock.

2. Take out and disconnect existing switch for replacement (for

multiswitch installation, identify the wire connected on the
" common " screw).

3. Reconnect each disconnected wire to the timer according to the

appropriate wiring diagram.

4. Put back switches correctly into their electric box.

5. Return power at circuit breaker.

EXISTING 3-WAY INSTALLATION

To replace a 3-way switch with this wall switch, use the following
diagram :

TO VERIFY OPERATION

Refer to " POWER-ON " section to start the wall switch. Try turning on
lights with remote switch and wall switch. Installation is completed if
operations run well. If it does not function properly, interrupt power at
circuit breaker and rewire the jumper on the remote switch between the
" common " screw and the other screw.

A NEW 3-WAY INSTALLATION

For a new installation, a single pole switch can be used at the remote
location. Use the following wiring diagram :

Note: The jumper wire provided is not used for this installation.

POWER-ON

1. Open the wall switch door using a small screwdriver.
2. Ensure that the fuse is properly installed
3. Press on the " reset " button using a paper clip.
4. On the display, " 0:00 " and " MO " should flash.

If there is nothing on the screen, check the following points :

a) Maybe the fuse is not present in the switch.

b) If the wall switch controls a lamp equipped with an on/off switch,

make sure the lamp switch is in " ON " position.

THE TI052A-3W WALL SWITCH CAN OPERATE ON :

ballast equipped installations such as : fluorescent lamps, sodium
lamps, etc.

incandescent and halogen lighting

contactor equipped installations, ceiling fan, block heater, etc.

The " common " wire identified on the removal 3-way switch must be
connected on either black wall switch wires. Connect the two other wall
switch wires to the two remaining wires.

On the remote switch, connect the jumper wire between the " common
" screw of the switch and the screw where the second black wall switch
wire is connected. Once wiring is completed, put switches back in their
electric box and return power at circuit breaker.

720-052002 1/2