Alignment and adjustments, Test mode, Special test mode – Samsung DV361GWBEWR-A3 User Manual

Page 3: Sensor bar touch data mode, Cycle count mode, Warning

Advertising
background image

3

TEST MODE

Continuous Run Mode:
1.
Press Signal + Dry Level for 3 sec during Power On State (Normal User Mode) .
2. Once in Continuous Run Mode, 7-Segment will toggle display “total cycle” and the remaining

time.

3. The previous cycle will restart during Continuous Run Mode until continuous run mode is

disabled.

4. During Continuous Run Mode, press Signal + Dry Level for 3 seconds to return to normal user

mode. 7-segment will no long display “total cycle ” and only display the remaining time.

Special Test Mode

Definition of Special Test Mode:
-

Dryer must be on before Service Mode can be entered.

-

Press Signal and Temp Keys for 3 seconds, or until 3 beeps are heard.

-

The machine will now be in Service Mode.

-

Upon entry into Service Mode, the Sensor Bar Touch Data will be shown (Default Special Test

Mode).

How to Enter:
-

To enter Special Test Mode press Signal and Temp Keys for 3 seconds or until the control

beep.

Sensor Bar Touch Data Mode

Definition of Sensor Bar Touch Data Mode:
-

Dryer will display Sensor Bar data, This mode is default mode of entering Special Test Mode

Cycle Count Mode

Definition of Cycle Count Mode:
-

Cycle Number executed will display.

How to Enter:
-

To enter Cycle Count Mode press “Wrinkle Prevent” key while in Special Test Mode.

ALIGNMENT AND ADJUSTMENTS

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.

Technical_information-02365J-01_EN.indd 3

2012-09-11 �� 3:09:09