AMX NXA-UPSEPM NXA-UPS1500EPM User Manual

Nxa-ups1500epm, Installation guide

Advertising
background image

Installation Guide

NXA-UPS1500EPM

Extended Power Module

NXA-UPS1500EPM Extended Power Module

NXA-UPS1500 EPM Extended Power Module (FG 678-16) works with the
NXA-UPS1500 Uniterruptible Power Supply to increase the duration of
backup power, providing up to 3X additional battery run time (FIG. 1).

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

This manual contains important instructions that should be followed during
installation and maintenance of the EPM and batteries.

IMPORTANT NOTICE

• This EPM connects to an UPS. There will be voltage at the output

terminals if the UPS is turned on even if the input AC Mains is not
available.

• To eliminate any overheating of the EPM, keep all ventilation openings

free from obstruction and do not place any foreign objects on top of the
EPM. Keep the EPM 8” (20cm) away from the wall.

Note: EPM connectors are color coded. Do not try to install the EPM
with connectors that are a different color from the EPM connector in
the UPS.

• This EPM is not designed for use in dusty, corrosive and salty

environment.

• The battery will discharge naturally if the system is unused for a period

of time.

Note: The EPM module is approx. 27.5~110.2 lbs. (12.5~50 kgs), be
cautious when unpacking and lifting the unit to avoid injury.

• It should be recharged every 2-3 months if unused. During normal

operation, the batteries will automatically remain in charged condition.

• When replacing batteries, replace with the same quantity, type &

capacity.

• CAUTION - Do not dispose of battery or batteries in an open fire.

The battery may explode.

• CAUTION - Do not open or mutilate the batteries. The electrolyte

from the batteries is toxic and harmful to the skin and eyes.

• CAUTION - Risk of Electric Shock - Battery circuit is not isolated

from AC, hazardous voltage may exist between battery terminals
and ground. Test before touching with bare hands.

• CAUTION - A battery can present a risk of electrical shock and

high short circuit current. The following precautions should be
observed when working on batteries:

1.

Remove watches, rings, or other metal objects.

2.

Use tools with insulated handles.

3.

Wear rubber gloves and boots.

4.

Do not lay tools or metal parts on top of batteries.

5.

Disconnect charging source prior to connecting or
disconnecting battery terminals.

EPM Specifications

Nominal System Voltage: 24V
Connector color: Red (+), Black (-)

Related Documents

Refer to the NXA-UPS1500 Uninterruptible Power Supply Operations/
Reference Guide
(available online at www.amx.com) for additional
information, including instructions on replacing the batteries and
rack-mounting the UPS and EPM.

Installing the EPM

The packing condition and the external outlook of the unit should be
inspected carefully before installation. Retain the packing material for future
use. The EPM includes accessories for tower and rack mount (FIG. 2).

Selecting Installation Position

It is necessary to select a proper environment to install the unit, in order to
minimize the possibility of damage to the EPM and extend the life of the
batteries.
Please follow the instructions below:
1.

Make sure the EPM is installed within the proper environment as
specified. (0-40°C and 30-90% non-condensing humidity)

2.

This EPM is designed for indoor use only.

3.

Ensure the installation site environmental conditions are in
accordance with the EPM working specifications to avoid overheat
and excessive moisture.

4.

Do not block the air-flow to the ventilation openings of the unit.

5.

Keep at least 20cm (8’) clearance from the rear panel of the EPM from
the wall or other obstructions.

Note: In order to mount the EPM into an equipment rack, you must use a
rack shelf (not included with the EPM).

FIG. 1 NXA-UPS1500 EPM Extended Power Module

Release tabs

(rear)

(front)

EXT.BAT. terminal

UPS BAT. terminal

(to second or next EPM)

(to the NXA-UPS1500)

Release tabs

To access batteries, remove the screw covers and the screws beneath the tabs

.

Grounding screw

(connects the Grounding

wire to the NXA-UPS1500)

Grounding screw

(connects the Grounding

wire to the second or next EPM)

FIG. 2

EPM Accessories for Tower and Rack Mount

Advertising