Checking leds – Allied Telesis AT-PWR02 User Manual

Page 14

Advertising
background image

Installation Guide

13

Checking LEDs

LEDs on PSUs, fans, and the front panels of switches indicate the operational
status of the devices. After you have installed a PSU or fan and have powered on
the switch, check the LEDs to verify operation by using the following tables.

PWR01
PWR02

The following table describes LEDs on the PWR01 and PWR02 power supply
units.

PWR05

The following table describes LEDs on the PWR05 power supply unit.

FAN01

The following table describes LEDs on the FAN01 fan-only module.

FAN03

The following table describes LEDs on the FAN03 chassis fan module.

LED

State

Description

FAULT

Red

The temperature on the PSU has exceeded the limit of
75º C (167º F), or the fan failed.

PWR
GOOD

Green

A PSU is installed in the switch and is delivering power.

LED

State

Description

~

Green

AC input voltage is within 90-264VAC, 47-63Hz.

Off

AC input voltage is outside the acceptable range.

Green

DC output voltage is within 12V +/- 10%.

Off

DC output voltage is outside the acceptable range.

Red

A fault has occurred. There is either a fan failure, or the
temperature has exceeded its limit of 70ºC (158ºF).

Off

No fault conditions detected.

LED

State

Description

FAULT

Red

The fan has failed.

LED

State

Description

FAN
STATUS

Red

The fan has failed.

Advertising