Initial Configuration and Firmware Upgrade

19

NI Series WebConsole & Programming Guide

16.

Cycle power to the Master (unplug and reconnect power to the unit).

17.

After Studio has establish a connection to target Master, click the OnLine Tree tab of the
Workspace window to view the devices on the System. The default System value is one (1).

18.

Right-click the associated System number and select Refresh System. This establishes a new
connection to the specified System and populates the list with devices on that system.

The communication method is highlighted in green on the bottom of the NetLinx Studio window.

Resetting the Factory Default System and Device Values

1.

In NetLinx Studio, access the Device Addressing dialog (FIG. 1 on page 5) by either one of these
two methods:

Right-click on any system device listed in the Workspace and select Device Addressing.

Select Diagnostics > Device Addressing from the Main menu.

2.

Click the Set Device/System to Factory Default button. This resets both the system value and
device addresses (for definable devices) to their factory default settings. The system information (in
the OnLine Tree tab of the Workspace window) refreshes and then displays the new information.

3.

Click Done to close the Device Addressing dialog.

4.

Click Reboot (from the Tools > Reboot the Master Controller dialog) and wait for the System
Master to reboot.

The STATUS and OUTPUT LEDs should begin to alternately blink during the incorporation. Wait
until the STATUS LED is the only LED to blink.

5.

Press Done once until the Master Reboot Status field reads *Reboot of System Complete*.

6.

Click the OnLine Tree tab in the Workspace window to view the devices on the System.

The default System value is one (1).

7.

Right-click the associated System number (or anywhere within the tab itself) and select Refresh
System
. This establishes a new connection to the specified System and populates the list with
devices on that system.

8.

Use Ctrl+S to save these changes to your NetLinx Project.

This process of cycling power acts to reset the updated NetLinx Control Card and
detect its new firmware update. It also serves to allow the Integrated Controller to
detect and reflect the new firmware on the card to the NetLinx Studio display on the
Workspace window.

By setting the system to its default value (#1), Modero panels that were set to
connect to the Master on another System value will not appear in the OnLine Tree
tab of the Workspace window.
For example: A Modero touch panel was previously set to System #2. The system is
then reset to its default setting of System #1 and then refreshed from within the
Workspace window. The panel will not reappear until the system is changed (from
within the System Connection page on the Modero) to match the new value and both
the Master and panel are rebooted.