Spire corp – Spire CHARGER 511 / SP-AD-511BK-EU User Manual

Page 4

Advertising
background image

Version:A/0 Page 4 of 7

Spire Corp.

Http://www.spirepower.com & Http://www.spirecoolers.com

Http://www.spire-corp.com





4 Output Characteristics

4.1 Static Load

Voltage Minimum

load Maximum

load

+5V 0A

1.0A

4.2 Output Voltage

The output voltage shall be statically regulated for all combinations of load, line and

environment including cross regulation as shown.

Voltage Range Tolerance

+5V +4.90V~5.20V ±5%

4.3 Ripple & Noise Voltage

Voltage

5V at full load

Ripple & noise voltage

<100mVp-p

Measuring is done by 20MHz bandwidth oscilloscope and terminated each output with a

10uF capacitor and a 0.1uF capacitor

4.4 Hold-UP Time

10 msec minimum from loss of nominal AC input at full load condition, 110VAC/60Hz

input, output will remain within regulation

4.5 Efficiency

The efficiency (watts out / watts in) is higher than 70% typical while measuring at

nominal line and rated load

4.6 Turn on delay time

During turn on and turn off, no voltage shall exceed its nominal voltage by more than

2% and no output will change its polarity with respect to its return line. All output shall reach

their steady state values within 1 seconds of turn on.