Spire corp – Spire CHARGER 511 / SP-AD-511BK-EU User Manual

Page 5

Advertising
background image

Version:A/0 Page 5 of 7

Spire Corp.

Http://www.spirepower.com & Http://www.spirecoolers.com

Http://www.spire-corp.com

5 Protection Requirement

5.1 Short Circuit Protection:

The adapter is protected that a short happened between the output terminals and shall

not result in a fire hazard, any damage to this adapter and will be normal operation

automatically while the short is removed.

5.2

Over Voltage Protection

The power supply shall be shutdown when5V output voltage reaches to its over –

voltage protection trigger point 9.0V Max

5.3

Over – current protection

No damage to the power supply shall be sustained when operating any output
under any line condition, into an over load condition for an indefinite period of
time. The power supply shall be self – recovering when fault condition remove.

6 Environmental Requirement

6.1 Operating

The power supply shall be capable of operating continuously in any mode without

performance deterioration in the following environmental conditions.

Operating : 0℃~40℃

6.1.1 Ambient Temperature: 0℃ ~45℃

6.1.2 Relative Humidity : 20% ~ 90%

6.2 Non-Operating

6.2.1 Ambient Temperature: -20℃ ~55℃

6.2.2 Relative Humidity : 20% ~ 90%.

7 Mechanical Requirement

7.1

Dimension: 73.7(L)*27.5(W)*80(H) mm

7.2 Weight:

60g

Advertising