Instruction manual for simple measurement (1), Instruction manual for simple measurement (2), General (1-point) measurement – Nikon Laser User Manual

Page 2

Advertising
background image

Display linear distance.

POWER

button

Push

Keeping the

button pressed

allows continuous

measurement of

up to 20 seconds.

Measurement

Display of horizontal distance.

After POWER is

turned on.

Aim at the target.

Switching measurement modes with MODE button in the status of Limited/

Full mode.

(See separate “Measurement and Display” sheet for switching between Full and

Limited modes.)

Press and release MODE button to switch measurement mode.

Note: Holding down MODE button longer switches the display unit.

Instruction manual for simple measurement (1)

General (1-point) measurement

(Measurement order: Ⅰ⇒Ⅱ⇒Ⅲ⇒Ⅳ⇒Ⅱ , then repeat)

Ang

Hgt

Act

Hor

Target point

Rangefinder (eyes)

Internal display

(”Linear distance mode”)

(Display will be different depending on the setting mode.)

Result is stored until next

measurement starts.

Default: “Last Use” settings.

First target priority setting.

End of measurement is indicated

with --- and no display of .

Measurement values of the “Last Reading” are displayed

on external LCD when terminating measurement.

Power turns off 30 seconds

after the last operation.

Limited/Full mode

When the MODE button is pressed, data in each

measurement mode is displayed in sequence.

When the POWER button is pressed with the

selected mode, measurement and display are made

in that measurement mode.

Display of the target’s

height from the

rangefinder’s (eyes’)

level.

Display angle

(from horizontal).

Display of the vertical separation

(height between two points).

No data displayed.

Full mode

External LCD

Act (Linear distance)

Hor (Horizontal distance)

Hgt (Height from horizontal)

Ang (Angle from horizontal)

All data below is displayed simultaneously.

This symbol indicates the display is

blinking.

Measuring vertical separation (height between 2 points)

1st target point

2nd target point

Rangefinder (eyes)

Internal display

Display when the

vertical separation

(height between

two points) mode is

selected.

First target priority mode.

Power turns off automatically

after 30 seconds without

operation.

Aiming at the

1st point.

Display of the height

from horizontal level of

1st point.

POWER

button

Push

Measurement

Result is stored until

next measurement

starts.

When the MODE button is pressed, data of

2nd target point in each measurement mode is

displayed in sequence.

Pushing the POWER button in the selected

measurement mode, measurement and data

display in that measurement mode are made.

This symbol indicates the display is blinking.

Aiming at the

2nd target point.

POWER

button

Push

Measurement

Display of the

vertical separation

(height between

two points).

Display changes

automatically after 2

seconds.

External display

After the measurement of 1st

target point.

◎ After the measurement of 2nd target point.

(Display of the vertical height between two points.)

Display of the data of 2nd target point by

pressing the MODE button in the status of Ⅶ’.

247.2

Act(1)

224.0

Hor(1)

25.0°

Ang(1)

104.5

Hgt(1)

227.5

Act(2)

247.2

Act(1)

15.0°

Ang

65.0

Hgt+Hgt2

224.0

Hor(2)

10.0°

Ang(2)

39.5

Hgt(2)

227.5

Act(2)

E E

Limited mode

Full mode

Act: Linear distance

Hor: Horizontal distance

Hgt: Height from horizontal (eyes)

Hgt + Hgt2: Vertical separation

(height between 2 points)

Ang: Angle (from horizontal)

Instruction manual for simple measurement (2)

(Measurement order: Ⅰ⇒Ⅱ⇒Ⅲ⇒Ⅳ⇒Ⅱ , then repeat)

Advertising