Prerequisites for the appliance's stability, Operation, Description of the appliance – Karcher SCP 16000 IQ Level Sensor User Manual

Page 15: Preparing the appliance, Automatic operation

Advertising
background image

– 3

Caution
Create stability for the appliance prior to all
work on or with the appliance to prevent acci-
dents or damage.

The stability of the appliance is warranted
when it is placed onto an even surface.

1 Mains cable with plug switch for auto-

matic/ manual operations

2 Level switch (IQ Level Sensor)
3 Stainless steel prefilter
4 Ventilation button
5 Carrying handle
6 Flat seal
7 Backflow valve
8 Hose connection 1" (25.4 mm)
9 Hose connection 1

1

/

4

“ (25.4 mm)

10 Union joint
11 Cable connector

Please follow the safety instructions before
start-up!
Illustration

Slide the acorn nut over the selected
hose connection.

Place the flat seal into the hose connec-
tion piece.
If you would like to prevent the water
that is standing in the hose or above the
pump after the pump has been turned
off, we recommend that you use the in-
cluded backflow valve. Before inserting
the backflow valve, the flat seal must be
removed. Pay attention to correct posi-
tioning.

Screw the suction hose with the union
joint on the pump

Push the hose on the hose connection
and fasten it with appropriate hose clip

Note:
The larger the hose diameter and the short-
er the hose, the higher the feed rate.
Illustration

Unfold the folding legs if you are work-
ing without pre-filter (only SCP 16000 ).

Illustration

Install the pre-filter depending on the
level of impurities in the fluid to be trans-
ported (for e.g. leaves or plant fibre).

Illustration

In Automatic mode set the IQ Level
Sensor to the desired switching height.
The IQ Level Sensor can be removed
from the guide rail toward the top and
placed separately if necessary.

Illustration

Place the pump on a level, stabile sur-
face in the liquid to be transported, en-
sure that it is standing firmly or immerse
it using a rope tied to the handle.
The suction area should not be blocked
fully or partially through the impurities.

The liquid level must at least be 3 cm (SCP
16000) and 8 cm (SDP 18000) for the pump
to suck in liquids independently.
If the liquid level is less than 4 cm (only
SCP 16000), proceed according to instruc-
tions in the chapter of flat suction.

Insert the plug in the socket and select
one of the following operating modes.

In the automatic mode, the IQ Level Sensor
controls the pumping operations. The
pump starts when the fluid level reaches
the IQ Level Sensor. The pump switches off
automatically after 10 to 60 seconds (de-
pending on the ambient conditions) when
the fluid level falls below the IQ Level Sen-
sor. The pump automatically conducts the
adaptation to the necessary trail time/pump
time. Thi setting remains saved for a max.
of 24 hours or until the mains plug is pulled
out. If the mains plug is pulled prior to the
24 hour time period, or after the 24 hours
have elapsed, the pump will automatically

Prerequisites for the appliance's

stability

Operation

Description of the Appliance

Preparing the Appliance

Operation

Automatic operation

15

EN

Advertising
This manual is related to the following products: