Troubleshooting, M danger, Fault – Karcher HDS 9-14-4 ST User Manual

Page 32: Possible cause, Remedy, Of whom, There is no voltage in the machine, Check electrical mains, Electrician, Safety time switch is on

Advertising
background image

-

11

ƽ

Danger

Risk of injury! The main switch of the vacuum cleaner is to be
switched off or the Cekon plug must be unplugged while carrying
out any repairs or maintenance jobs.

*
Note
Switch the plant off and then on to undo the burner failure.

**

Troubleshooting

Fault

Possible cause

Remedy

of whom

Machine is not running; indi-
cator lamp for operations
stand-by (F) is not glowing

There is no voltage in the machine. Check electrical mains.

Electrician

Safety time switch is on.

Switch off the appliance switch briefly and
switch it on again.

Operator

Fuse in the control circuit (F3) has
burnt off. Fuse is located in the
control transformer (T2).

Install a new fuse; if it burns out again, then
remove the cause for the over-loading.

Customer Service

Pressure switch HP (High pres-
sure) or LP (Low pressure) is de-
fective.

Check pressure switch.

Customer Service

Timer module (A1) defective.

Check connections, replace if required.

Customer Service

Exhaust thermostat (B8) tripped.

Allow plant to cool down. Unlock the exhaust
thermostat (B8). Eliminate the cause for the
disturbance.

Customer Service

+ Indicator lamp for engine
over-heating (G) is glowing

Thermal sensor (WS) in the engine
or the over-current protection
switch (F1) has got activated.

Rectify cause for over-loading.

Customer Service

The water shortage safeguard in
the swimmer tank has got activat-
ed.

Remove the water shortage.

Operator

Burner does not ignite or the
flame glows off during opera-
tion

Thermostat (B) has been set at a
very low temperature.

Set the thermostat to a higher level.

Operator

Machine switch is not positioned to
burner

Switch on the burner.

Operator

The water shortage safeguard in
the safety block has got switched
off.

Ensure adequate water supply. Check ma-
chine for leaks.

Operator

The indicator lamp Burner
failure (E) glows*

Fuel tank empty.

Refill fuel.

Operator

Fuel filter choked.

Clean fuel filter - to do that remove the fuel fil-
ter by turning, clean it and again turn it in.

Operator

Photo-cell flame monitoring device
has been set wrongly or is defec-
tive.

Check the correct positioning of the photo-
cell. **

Operator

No ignition spark exists (can be de-
tected through the sight glass in
the burner lid).

Check electrodes distance between ignition
transformer and ignition cable. Rectify the
distance or replace defective parts. Clean it,
if necessary.

Customer Service

Ignition motor is locked.

Removing the blockage. Remove the stop-
per (I) on the operating plan and unlock the
over-current protection switch. Insert back
the stopper.

Customer Service

Failure of hte fuel pump or the fuel
solenoid valve.

Check parts and replace defective parts.

Operator

32

EN

Advertising