APPENDIX 1. – RS-232 & RS-485 Codes

RJ-11 PIN configuration for RS-485

PIN NO.

PIN Assignment

1.

Not Connected

2.

Ground

3.

D -

4.

D +

5.

Ground

6.

Not Connected


CONNECTION

More than one device can be controlled via the RS-232 & RS-485 port from a host computer. Three kinds of

RS-232 & RS-485 command codes are used in the command set: Separation code, Key code, and Control

Command code. All the command codes are in ASCII code format as listed in the table below. The

transmission protocol is 8 data bit; 1 start bit, 1 stop bit and no parity. Four different speeds can be used, 1200

baud per second, 2400 baud, 4800 baud, and 9600 baud. The default setting is 2400 baud per second.

When only one device is controlled via RS-232 & RS-485 port from a host computer, the control command

codes should contain an “L0” to instruct the device to enter operation mode. Other command codes starting

with “L” are not necessary.

When a computer controls more than one device, use “LA” to instruct all devices to enter into stand-by mode.

Use “Lnnnn” to instruct a specific unit to enter into operation mode. “nnnn” represents the ID number of the

specific unit. Set the ID number for the device in the menu setup mode. (0 cannot be used for ID numbers)