2 general panel, 2 general panel – ATTO Technology 3100 User Manual

Page 14

Advertising
background image

11 ATTO Technology BridgeTools Installation and Operation Manual

4.2 General panel

The general panel provides some basic information about the FibreBridge. A message box at the bottom
of the panel displays useful hints and suggestions. Clicking on the help icon will give a detailed
explanation of each parameter, the possible values to enter and how the FibreBridge will respond to each
selection. Some parameters will be “grayed out” if they do not apply to your model of the FibreBridge
or if they have no effect based upon the selected value of a related parameter.

Blink Ready LED (default = disabled)

Enabling this option causes the Ready LED on the front
panel of the FibreBridge to blink until you disable the
parameter. Helps to identify the particular FibreBridge you
are connected to in the SAN.

FibreBridge Name

An eight-character name assigned by the user to identify
each FibreBridge on the network to help identify and select
a specific FibreBridge.

FibreBridge Type

Read only: reports the type of FibreBridge in use.

Minimum Alarm Temperature

Sets and displays the enclosure temperature minimum
threshold value. An alarm will trigger if the enclosure
temperature drops below this value. Valid entries are
between 5 and 40 degrees C and must be below the
Maximum Alarm Temperature value.

Maximum Alarm Temperature

Sets and displays the enclosure temperature maximum
threshold value. An alarm will trigger if the enclosure
temperature goes above this value. Valid entries are between
5 and 40 degrees C and must be above the Minimum Alarm
Temperature value.

NVRAM Version

Read only: reports the revision level of the NVRAM within
the FibreBridge.

Power Status A

Read only: allows remote monitoring of Power Supply A
status. BridgeTools will report it as either OK or
Unavailable.

Power Status B

Read only: allows remote monitoring of Power Supply B
status. BridgeTools will report it as either OK or
Unavailable.

Serial Number

Read only: serial number of FibreBridge currently
connected to BridgeTools.

Temperature

Read only: allows remote monitoring of the FibreBridge
internal temperature.

World Wide Name (WWN)

Read only: provides a guaranteed unique identifier for each
Fibre Channel port on the network. This information can be
used to persistently bind the port to a host target ID.

Some options will be “grayed out” on the panel: they are not available because of the type of access mode or FibreBridge model or they have no effect based on other

selections. The chart below shows options available based on model and access method.

Model/Access method

Options

2200/3200

in-band

2200/3200

Ethernet

2200/3200

serial port

4500

in-band

4500

Ethernet

4500

serial port

Blink Ready LED

FibreBridge name

FibreBridge type

Maximum Temperature

Minimum Temperature

NVRAM version

Power Status A

Power Status B

Serial number

Temperature

World Wide Name