Troubleshooting – Panasonic KITE18HB4EA User Manual

Page 9

Advertising
background image

9

ENGLISH

CANCEL

TIMER

ON

1

2

3

OFF

CLOCK

RESET

SET

CHECK

TROUBLESHOOTING

TROUBLESHOOTING

Symptom

Symptom

Check

Check

Heating/Cooling operation is not working

effi ciently.

• Set the temperature correctly.

• Close all doors and windows.

• Clean or replace the fi lters.

• Clear any obstruction at the air inlet and air outlet vents.

Noisy during operation.

• Check if the unit has been installed at an incline.

Remote control does not work.

(Display is dim or transmission signal is weak.)

• Insert the batteries correctly.

• Replace weak batteries.

The unit does not work.

• Check if the circuit breaker is tripped.

• Check if timers have been set.

The unit does not receive the signal from the

remote control.

• Make sure the receiver not obstructed.

• Make sure the remote control signal transmission is within the range.

• Certain fl uorescent lights may interfere with signal transmitter. Please

consult your nearest dealer.

Symptom

Symptom

Cause

Cause

Mist emerges from indoor unit.

• Condensation effect due to cooling process.

Water fl owing sound during operation.

• Refrigerant fl ow inside the unit.

The room has a peculiar odour.

• This may due to damp smell emitted by the wall, carpet, furniture or

clothing.

Indoor fan stops occasionally during automatic

fan speed setting.

• This helps to remove the surrounding odours.

Operation is delayed a few minutes after

restart.

• The delay is a protection to the unit’s compressor.

Outdoor unit emits water/steam.

• Condensation or evaporation occurs on pipes.

Timer indicator is always on.

• The timer setting repeats daily once set.

Power indicator blinks during operation and

the indoor fan is stopped.

• The unit is in defrost mode, and the melted frost is drained from the

outdoor unit.

Indoor fan stops occasionally during heating

operation.

• To avoid unintended cooling effect.

Power indicator blinks before the unit is

switched on.

• This is a preliminary step in preparation for the operation when the ON

timer has been set.

Cracking sound can be heard during

operation.

• Changes of temperature cause the expansion/contraction of the unit.

The following symptoms do not indicate malfunction.

The following symptoms do not indicate malfunction.

Check the following before calling for servicing.

Check the following before calling for servicing.

NOTE :

NOTE :

The unit stops and the timer indicator blinks.

The unit stops and the timer indicator blinks.

1

Press for 5

seconds.

3

Press for 5

seconds to

quit checking.

2

Press until you hear

beep sound, then jot

down the error code.

• Turn the unit off and reveal the error code to your nearest dealer.

• The unit may be operable

(with 4 beeps) on a limited

basis, depending on the

error.

Advertising