Page 83 | AlliedWare™ OS How To Note: IGMP

Example of bad choices for timer values > Example

Example of bad choices for timer values

It is generally unwise to change any of the default IGMP settings unless you have advanced
knowledge of how IGMP works. As

"Timer and counter relationships" on page 69

describes,

most of the timers and counters are related. This means setting timers can cause problems
unless you understand the potential impact on the IGMP process.

This example sets three timers to excessively short values and discusses the potential
consequences.

Example

Imagine the following changes to the configuration:

The commands to configure these settings are:

set ip igmp lmqi=5

set ip igmp queryresponseinterval=5

set ip igmp timeout=126

The resulting values are displayed in the following output.

Timer

New value

Last Member Query Interval

5

Query Response Interval

5

Default Timeout Interval

126

Manager Switch 1> show ip igmp

IGMP Protocol

------------------------------------------------------------------------

Status ........................... Enabled

Default Query Interval ........... 125 secs

Default Timeout Interval ......... 126 secs

Last Member Query Interval ....... 5 (1/10secs)

Last Member Query Count .......... 2

Robustness Variable .............. 2

Query Response Interval .......... 5 (1/10secs)

.

.

.