Balboa Water Group Ozone to Jet and Suction User Manual

Installation guide

Advertising
background image

INSTALL OZONE TO JET AND SUCTION

ELECTRICAL CONNECTION (Diagram A)
-Plug pump into piggy back plug on Ozone Generator
-Plug Ozone into switch box
-Connect switch box with ¼” ID tubing to tube side On/Off
air button. Or use optional electronic control

INSTALLATION GUIDE

Connecting the Ozone Generator to the suction side of the pump wet-end:

Option 1 (Reference Master Diagram)

-Drill out one of the 3/8” O.D. nipples on the suction
inlet port using a 3/16” drill bit.
-Connect one end of 3/8” ID tubing to the drilled out
nipple on the suction inlet port. Secure with band type
clamp.
-Connect the other end of 3/8” I. D. tubing to the check
valve barb and secure with wire clamp.
-Arrow on Inline Check MUST face towards the suction
inlet port nipple.

Option 2 (Reference Master Diagram)

-Drill a 3/8” hole in the suction line close to pump.
-Glue a Saddle Barb (Part # 00372 for 2”pipe, or Part # 00375
for 1.5” pipe) using PVC pipe cement on pipe surrounding
hole and area under barb

*

DO NOT GLUE OVER HOLE ON BOTTOM OF

SADDLE BARB
-Connect one end of 3/8” I.D. tubing to saddle barb and
secure with wire clamp.
-Connect other end of 3/8” I.D. tubing to the check valve barb
and secure with wire clamp.
-Arrow on Inline Check Valve MUST face towards the 3/8”
saddle barb.

NOTE: DO NOT GLUE TUBING TO BARBS!

Option 1

Option 2

Electrical Connection for Pump and Ozone Generator:

Part #99634 Air Switch Box w/20 min. timer
Part #99620 Electronic control with 20 min. timer

Diagram A

PLEASE READ COMPLETE INSTRUCTIONS BEFORE INSTALLATION

Connecting the Ozone Generator directly to the suction line:

40570 Rev A July 20, 2009

Advertising