3.3.2.2 Defining Number of FXO Ports Connected to PBX

The gateway's FXO port (located on the rear panel), interfaces with the PBX. By default, all the
gateway's FXO ports (eight for the MP-118; four for the MP-114) are enabled. However, if for any
reason the ports (endpoints) are disabled, you can enable them by performing the procedure
below.

¾

To enable the gateway's FXO ports, take these 4 steps:

1.

Open the ‘Endpoint Phone Number Table’ screen (Protocol Management menu >
Endpoint Phone Numbers

).

Figure 3-10: Endpoint Phone Number Table Screen

2.

In the 'Channel(s)' field, enter the gateway's port number that is connected to the PBX. You
can enter all the ports, by simply entering a range in the first table row (e.g., '1-8' for all eight
ports of the MP-118).

3.

In the 'Phone Number' field, enter any logical telephone number (e.g., '2000') for these
channels.

4.

Click Submit to save your settings.