WARNING

DISCONNECT POWER BEFORE RELAMPING OR WIRING THE FIXTURE.

READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION

TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL APPLICABLE NATIONAL

AND LOCAL ELECTRICAL/BUILDING CODES. FOR CODE INTERPRETATION, CONSULT LOCAL CODE AUTHORITY

RISK OF FIRE. PRODUCT FOR OUTDOOR INSTALLATION AND USE ONLY.

WARNING

CAUTION

!

!

!

WARNING

ENSURE THAT ALL POWER IS

DISCONNECTED PRIOR TO WIRING

!

REMOVE LOWER HOUSING:

FIXTURES WITH ONE-PIECE LOWER:

Lift lower housing hinge pins out of the hinges in the upper housing.

Slide lower housing off of hinge bar.

FIXTURES WITH POWER-PAD:

Unfasten the power-pad latch screw. NOTE: The power-pad is

HEAVY, and it should not be allowed to drop free and swing.

Disconnect the two sets of electrical connectors, and then unhook

the power-pad from the hinge bar and remove it.

MOUNTING / LEVELING:

Determine the size of the mast arm. This luminaire is designed to

accommodate a mast arm from 1/1/4" to 2" dia. The luminaire is

factory set to mount to the 1-1/4" arm. To mount to a 2" arm, two

modifications must be made.

1. The rear opening must be enlarged. Knockouts are cast-in

around the rear opening for this purpose. To remove this excess

material, strike with a hammer or grasp with pliers and break off.

2. The fitter bracket must be flipped over.

(This will require the complete removal of the fitter bolts.)

STANDARD MOUNTING:

Loosen (DO NOT REMOVE) the fitter bolts. Lift the luminaire into

position in front of the mast arm such that the mast arm enters

through the opening at the rear of the luminaire and between the

fitter bracket and the luminaire housing. The mast arm should rest

against one of the cast-in steps located in this area. Using these

cast-in steps, adjust luminaire to desired mounting angle. Tighten

fitter bolts to 10-12 FT/LBS.

CAUTION

OVER-TORQUING OF FITTER CLAMP BOLTS CAN

CREATE CRACKS IN THE HOUSING CAUSING

THE FIXTURE TO FALL TO THE GROUND.

!

INPUT VOLTAGE:

If the voltage available is different from that shown on the terminal block,

consult the wiring diagram for directions.

WIRING:

Feed the supply wires through the mast arm, dress them so they do not

interfere with any components, and connect them to the proper terminals

on the terminal block. Verify that supply voltage is correct as noted on

the terminal block label. Refer to the wiring diagram and the data on the

ballast for connection information and ratings.

INSTALLING LOWER HOUSING:

FIXTURES WITH ONE-PIECE LOWER:

Insert lower housing hinge pins into the hinge cradles of the upper

housing. Swing the lower housing into position and press firmly upward

until latch snaps into position. NOTE: IT IS NEVER NECESSARY OR

ADVISABLE TO SLAM THE HOUSING CLOSED!

FIXTURES WITH POWER-PAD:

To install the ballastry power-pad, engage the hinge hook with the hinge

bar on the upper housing. Connect the two sets of electrical connectors

firmly together. (These connectors are "polarized" so they will only fit

together one way.) Swing the power-pad closed. Fasten the latch screw

until it is firmly seated, but DO NOT OVERTIGHTEN IT.

MOUNTING / LEVELING (cont.):

CSA SPECIAL REQUIREMENTS:

Slide the weather guard onto the mast arm first. Carefully fold back the

insulating barrier along the score line to expose the fitter bolts. Install

the fixture as directed in the standard mounting instructions. Once

fixture has been installed, slide the weather guard along the mast arm

until it is firmly seated against the rear of the luminaire housing. Apply

RTV sealant between the weather guard and the housing creating a

water-tight seal. Once wiring has been completed, fold the insulating

barrier back into place.

APPLY RTV BETWEEN

GUARD AND HOUSING

MAST ARM

FITTER BOLTS

LEVELING STEPS

KNOCKOUT