INSTALLATION & MAINTENANCE INSTRUCTIONS

SIDELITE LUMINAIRE

American Electric Lighting a division of Acuity Lighting Group, Inc. Conyers, GA

DRAWING NO. B07796 REV E

©2003 ACUITY LIGHTING GROUP, INC.

PART NUMBER 057-71-07796

WARNING

DISCONNECT POWER BEFORE RELAMPING OR WIRING THE FIXTURE.

REAR HOUSING MUST BE GROUNDED TO REDUCE POTENTIAL OF ELECTRICAL SHOCK

READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION

SCREW (A)

FRONT HOUSING (B)

REFRACTOR

REAR HOUSING (D)

SCREW (E)

Clean reflector with mild soap or household type detergent.
Do not use acid or caustic cleaners.

1. Disconnect power to fixture.
2. Loosen screws (A) until free.
3. Open front housing & let hang on tethers.
4. Replace lamp and close front housing.

3. Install reflector, lamp and front housing.

Pull wires back through fixture & make connections in rear

housing compartment.

Loosen screws (E). Remove cover plate. Make wiring

connections. Replace plate.

1. Mount to 3 1/4" or 4" outlet box marked for wet location

using holes provided around outlet hole in rear housing.

1. Knock out 3 slugs in rear housing (D).
2. Mount with 3 bolts.

1. Loosen screws (A) until free.
2. Open front housing (B).
3. Remove screws holding tethers in rear housing.
4. Remove front housing.
5. Remove reflector by loosening its' two screws.

CLEANING

RELAMPING

MAINTENANCE

2. SIDE CONDUIT HOLES (OPTIONAL)

1. OUTLET HOLE

WIRING

OUTLET BOX MOUNTING

MOUNTING WITH 3 BOLTS

INSTALLATION

TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL APPLICABLE NATIONAL

AND LOCAL ELECTRICAL/BUILDING CODES. FOR CODE INTERPRETATION, CONSULT LOCAL CODE AUTHORITY

RISK OF FIRE. PRODUCT FOR OUTDOOR INSTALLATION AND USE ONLY.