Installation – Hawk Industries Spinner Manual 550 PNEUMATIC Serial Numbers 106 to 210 User Manual

Page 10

Advertising
background image

10

Installation

SC

SH

SH

S

1. Connect the Spring Hanger

(SH) to at least a 3/8"diameter

Steel Cable (SC) suspended

from a high point (as near the

crown as possible) in the der-

rick no more than 5 ft. from the

center of the Rotary Table.

2. Connect the lower end of the

spring hanger (SH) to the Spin-

master as shown. Make sure

the shackles (S) are tightened

securely. Make sure that the

Spinmaster hangs in the derrick

at a level that assures no contact

with any part of the stabbed tool

joint (including the upset) when

gripped on tube.

3. Hook a backup line to the rear

of the Spinmaster securing the

other end to the derrick. Make

sure the backup line is horizon-

tal and leaves little slack when

the Spinmaster is gripped on the

pipe so that no kick-back can

occur when changing spinner

motor directions.

Suspension

Caution

Hooking up the back-up line on an

angle not level with the spinner can

cause damage to the spinner case.

Part Name

Part #

Spring Hanger Assy. (SH)

002-50274

Part Numbers

Warning

Failure to properly hook up back-

up line could cause bodily injury.

Installation

Advertising