Power hook-up, Air spinmaster – Hawk Industries Spinner Manual 550 PNEUMATIC Serial Numbers 106 to 210 User Manual

Page 11

Advertising
background image

11

Installation

Power Hook-Up

Hydraulic Spinmaster

HIS

1. The hydraulic Spinmaster

requires a minimum hydraulic

pressure of 2000psi and a maxi-

mum pressure of 2500psi.

2. The hydraulic Spinmaster re-

quires a minimum hydraulic

volume of 20 GPM and a maxi-

mum of volume of 30GPM.

3. Connect (at least) a 3/4" hy-

draulic pressure hose (3000psi

working) to the hydraulic inlet

side ( HIS ) of the Spinmaster

valve as shown.

4. Connect (at least) a 1" hydrau-

lic return hose (250psi working)

to the hydraulic outlet side(HOS)

of the Spinmaster valve as

shown.

ASL

HRL

HRL

1. Connect the three supply hoses

(supplied with the Spinmas-

ter): the Hydraulic Return Line

(HRL), the Hydraulic Pressure

Line (HPL), and the Air Supply

Line (ASL) to the Spinmaster

and the Air Power Pack (APP)

as shown.

Continued on Next Page

APP

Note

Hydraulic filtration (at least 25

micron) is highly recommended

for Spinmaster for performance

and reliablity.

Air Spinmaster

ASL