Changing the spinner chain – Hawk Industries Spinner Manual 550 PNEUMATIC Serial Numbers 106 to 210 User Manual

Page 23

Advertising
background image

23

Maintenance & Repair

Changing the Spinner Chain

Tools Required

1. Make sure the Spinmaster is off

the drill pipe connection and in

the rest position on the derrick.

2. Shut down the Air Power Pack

or the hydraulic power unit.

3. Bleed any hydraulic and/or air

pressure from the Spinmaster ,

by cycling the door valve lever;

Make sure the doors are fully

open.

4. Assume that there is still a load

on every actuator. Proceed with
caution.

Initial Steps

1. Make sure the Spinner doors

(SD) are fully open.

2. Use the 7/8" wrench to loosen

the Spacer Bolts (B).

3. Use the 7/16" wrench to remove

the four rubber Safety shield

bolts (SB).

4. Remove the rubber Safety shield

(SS).

5. Remove the Spacer Bolts (B)

and Spacers (S).

SS

Continued on next page.

SD

SB

S

B

Chain

7/8" wrench, 7/16" wrench, Hammer, Nee-

dle-Nose Pliers

Advertising