Installation

Power Hook-Up, Con't

2. Connect a 1 1/4" air supply line

(ASL) from the air source to the

Air Power Pack (APP) as shown.

3. To turn on air, rotate Air Supply

Valve (ASV) counterclockwise

as shown.

ASL

Hydraulic Adjustments

1. Always adjust the Spinmaster

relief valve (RV) above main

system hydraulic pressure or

over heating of oil may result.

To adjust the relief valve, grip

the Hydraulic Spinmaster on

the pipe (see item #1 on page

#17). Use a 4mm Allen wrench

to screw the Spinmaster Relief

Valve (RV) counter-clockwise

until a hydraulic flow sound is

heard, then rotate clockwise

until sound (flow) stops.

2. The hydraulic Spinmaster comes

standard with an open center

valve configuration. The stan-

dard valve can be re-configured

to closed center by removing

the Open Center Plug shown

(PS) and replacing it with a

Closed Center Plug (CCP).

RV

PS

Part Name

Part #

Closed Center Plug (CCP) 25804

Open Center Plug (PS)

660312003

Part Numbers

CCP

APP

WARNING

It is recommended that a air regula-

tor from the source air to the power

pack be used (1 1/4"Pipe or larger).

Excess chain and drive roller wear

do to slipping may result if the

Spinmaster air power pack receives

more than 100 psi air pressure.