Operation

Operation

1. Swing Spinmaster toward pipe

until its chain is touching the

pipe tube. While continuing to

load Spinmaster (SM) against

the pipe, push door valve (DV)

handle away from you, fully

toward the Spinmaster (Detented

Position). The doors will close

and the Spinmaster will grip the

pipe.

2. To spinning is complete, pull

out on the Air Motor Valve

Lever (PMV), or push in on the

Hydraulic Motor Valve Lever

(HMV) depending on which unit

you are operating.

3. After the pipe shoulders, re-

lease the motor valve and the

Spinmaster will stop.

4. To remove the Spinmaster

from the pipe, pull back on the

Door Valve Lever (DV) and pull

the Spinmaster away from the

AIR SPINNER CONTROLS

DV

DV

PMV

Warning

When gripping the Spinmaster on

the drill pipe, always keep push-

ing the Spinmaster toward the pipe

while doors are closing or dam-

age may result to the front of the

Spinmaster.

SM

DV

HMV

HMV

HYDRAULIC SPINNER CONTROLS