22 Maintenance & Repair

Lubrication

RP

1. Make sure the gear box oil level

reaches the top pipe plug (RP).

2. Check for any oil leakage from

the gear box seal by looking at

the top or the drive shaft.

Lubricant Required
85-90 weight gear oil

SAE #AGMA5

Check Oil Level Once per Month

Reducer Gear Box

MGV

MGF

Grease after overhaul

1.Remove motor grease vent plug

(MGV). Use a grease gun to

fill the air motor gear box at the

motor grease fitting (MGF) until

grease begins to flow from the

vent (MGV).

2. Replace the vent plug (MGV).

Lubricant Required
Lithium Base #2 High Temperature

Grease. Use Lo-Temp Grease in tem-

peratures -20 deg. F or below.

Air Motor Gear Box

NOTE

Consistent lubrication of the Spinner

increases performance and compon-

nent life.