The two PWR LEDs on the Installation

Repeater will illuminate when AC power is
connected to the unit. There is no on/off
switch.

The two DATA LEDs will illuminate and

flicker rapidly to indicate that DMX data is
being received.

Two TEST indicators are associated with

the DMX input and each of the six outputs.
Refer to the Cable Test Feature instruc-
tions.

Indicators

Power
Supply:

Universal input (90-250V,
50/60Hz), 0.2A

Isolation:

2500V Opto-isolation on DMX lines
4000V Mains isolation

Protection:

Up to 250VAC/DC on all
port pins

Protocols:

DMX512 , DMX512-A, or any EIA422
or 485 based simplex protocol

Size:

19 x 10 x 3in. (483 x 254 x 76 mm)

Specifications

DMX512-A Compliance

The Pathway Installation repeater is com-

pliant with DMX512-A under the non-
compatible connector (NCC) provision.

All ports are DMX512-A protected to

250V with self-healing circuitry.

Subject to change without notice

103 Inglewood Plaza 1439 17Avenue SE Calgary AB, Canada T2G 1J9 • +1 403 243-8110 Fax +1 403 287-1281

Printed in Canada R8

D -

ON

Data present on

D + ON

incoming DMX line

D -

OFF

D- signal missing

D + ON

or shorted to common

D -

ON

D+ signal missing

D + OFF

or shorted to common

D -

OFF

No data present on incoming

D + OFF

DMX line

via the input connection, as per the previ-
ous instructions. Once that is verified, dis-
connect the cable to the suspect output
channel and depress the corresponding
ISO OUT TEST button. If both the corre-
sponding D- and D+ LEDs illuminate, this
shows that the isolated output circuitry
inside the repeater is working properly and
is transmitting both DMX512 signals. If
not, there is likely a problem with the out-
put circuitry for that channel. Try using the
spare transceiver chip to remedy the prob-
lem. Now reconnect the cable to the sus-
pect output and perform the same test. If
both of the D- and D+ LEDs illuminate, this
shows that there are no shorts in the out-
put cabling or connected receiving de-
vices. If one or both of the LEDs is off or
dim, a cable or device problem is indi-
cated. NOTE: if an output TEST button is
pushed when a proper input signal is not
being received by the Installation Re-
peater, the outputs will be in their normal
“idle” state (i.e. D- low level, D+ high
level), therefore the D+ LED will illuminate
and the D- LED will not.

INPUT TEST

INDICATIONS

Cable Test Feature cont.

4802 Installation Repeater

6-way opto-isolated DMX splitter

To ensure trouble free operation, DMX512
standards require that DMX devices be
installed in a daisy chain, with no tees,
wyes or stars in the DMX wiring. However,
site conditions may make star wiring
desirable or even mandatory. A Pathway
DMX Repeater permits star wiring by
making each branch of the star function
electrically as its own entity, unaffected by
the other branches of the star.
Additionally, opto-isolation circuitry
isolates each branch to prevent ground
loops or accidental damage from fault
voltages on DMX lines.

Operational Philosophy

• All cabling must be in a continuous run,

daisy-chained, no “Tees” allowed

• “Stars” are permitted only in conjunction

with a repeater

• Cable shield may be earth-grounded at

one end only, preferably at the control
console

• Maximum length of one cable segment

is 1,800 ft. (550m)

• Receiving devices have male

connectors, transmitters have female

• The last DMX device on the line must be

terminated with a termination switch or
resistor with a value of 100 to 120 ohms

between pins 2 and 3.

• 5 pin XLR type DMX connectors are

standard:

Pin 1:

Common

Pin 2:

Data (-)

Pin 3:

Data (+)

Pin 4:

Optional Data (-)

Pin 5:

Optional Data (+)

• Cable must be Belden 9842 (120Ω),

9829, 9729 (100

Ω), ISO/IEC 11801

(Cat5)

or equivalent

• A maximum of 32 DMX receiving

devices can be present on a single DMX
line

DMX Wiring

I

NSTALLER

S

G

UIDE

4802 Installation Repeater

6-way opto-isolated DMX splitter

Mounting

Installation Repeaters are designed for

indoor use, in a dry location. Mount the
Installation Repeater with appropriate fas-
teners to the wall. Run conduit into the
box through the knockouts provided, en-
suring that line voltage wiring is kept inside
the barriered power supply section.

An essential component of any
DMX512 distribution system, the
Installation Repeater permits star
wiring installations while isolating
a n d p r o t e c t i n g c o n n e c t e d
equipment from harmful electrical
f aul t s. P athw ay In st all atio n
Repeaters feature self-healing
protection devices on all ports to
prevent internal damage when
severe faults of up to 250V are
accidentally applied to the
connected DMX cabling. To help
you resolve any cable, signal or
component issues fast, there are
useful test functions built right into
the product.