页 22 – Minka Group F689-WH User Manual

Page 22

Advertising
background image

SYMPTOM

Fan Wobble

SOLUTION

NOTE:All blade sets are grouped by weight. Because wood and plastic

blades vary in density, the fan may wobble even though blades are

matched.

Make sure outlet box is secured to building structure, if necessary use

the wood screws provided to further secure outlet box to joist.

Make sure hanger bracket is secure to the outlet box, screws are tight.

Use the balancing kit provided if the wobble is excessive (follow

instructions included with balancing kit)

SYMPTOM

Fans/Light Turn on and Off Unexpectedly

SOLUTION

This is caused by interference. Please see “Freduency interference” for step

to charge the frequency.

SYMPTOM

Frequency Interference

SOLUTION

1.Turn the power off to your ceiling fan.

2.Please use a small size tool to change the frequency settings on the control

system.

3.Return power to the unit.

Note:After the AC power is on, do not press any other button on the

transmitter before pressing the “Stop” button,doing so will cause the

procedure to fail.

4.Within 60 secounds of turning the fan’s AC power ON. Press the

transmitter’s “Stop” button and hold the “Stop ” button for 10 seconds.

i

5.Once the receiver has detected the set frequency, the down light of your fan

if applicable will blink twice.(there is no indication if your fan is not equipped

with a light).

6.The receiver has now learn the frequency which has been selected on the

transmitter. After completing the steps above,you should be able to operate

the ceiling fan and light. If the fan is not responding to the transmitter. please

turn the power off to the receiver,and repeat the process.

Advertising