Manual 15000002 Rev 2

Page 1 of 4

Operation Manual

Flow Switches

(Models AP74 and AP74B)

A. General information

The AP74 and AP74B flow switches are used in gas delivery systems to signal an increase in
flow above a trip point. The signal is transmitted by a closed or open electrical contact from a
reed switch. The signal is typically monitored by a controller, which closes an isolation valve in
the gas delivery system when an “excess flow” signal is received. Many models are available
with different operating characteristics (pressure ratings, trip points, etc.) and porting
configurations.

Refer to the appropriate catalog data sheet for specific product information.

Product Note PN 423 is the application guide for flow switch sizing, installation, and
troubleshooting. It is available on the AP Tech website (www.aptech-online.com). Click the
“Tech Briefs” tab at the top of the page and scroll down to “Product Notes”.

To assist in flow switch selection, an online calculator tool is also found on the website. Access
the tool in the lower left corner of the home page by clicking the tab marked “Flow Trip Point
Calculator”. Enter gas and pressure conditions and read the calculated trip points adjacent to the
flow switch models.

B. Installation

1. Prior to installation, verify that the operating characteristics of the flow switch as

described below are appropriate for the system in which it will be installed.

a. Verify the materials of construction are compatible with the intended process gas.

b. Verify the pressure and temperature ratings are acceptable for the intended application.

c. Verify that the trip point of the flow switch is appropriate for the application.

d. Verify that the flow switch will be used in gas service only.

2. Inspect the flow switch to determine the flow path through the device and how the flow

switch will need to be installed in the system.

a. The AP74 has a flow arrow on the model number label on the body that indicates the forward

flow direction.

b. The AP74B has a flow arrow on the model number label on the body of the switch in the

bypass line that indicates the forward flow direction. The forward flow direction in the
AP74B main line is parallel to the flow in the bypass line.

3. Ensure there are no sensitive electronic devices near the intended installation location.

The flow switch contains a strong magnet that could adversely affect these devices.
Ensure there are no strong magnets near the AP74 or AP74B. A strong magnet can